Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
5.804
·
Velocity:
5.34
ft/sec
⚠ high velocity
SDR-9 · 250 PSI · 1" · 10 GPM
SDR-9 · 250 PSI · 1" · I.D. 0.875" · 10 GPM · 5.804 PSI/100ft · 5.34 ft/sec ⚠ high velocity
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.