Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
7.774
·
Velocity:
6.02
ft/sec
⚠ high velocity
SIDR · All PSI · 3/4" · 10 GPM
SIDR · All PSI · 3/4" · I.D. 0.824" · 10 GPM · 7.774 PSI/100ft · 6.02 ft/sec ⚠ high velocity
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.