Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
0.368
·
Velocity:
1.79
ft/sec
SDR-9 · 250 PSI · 2" · 12 GPM
SDR-9 · 250 PSI · 2" · I.D. 1.653" · 12 GPM · 0.368 PSI/100ft · 1.79 ft/sec
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.