Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
8.850
·
Velocity:
6.63
ft/sec
⚠ high velocity
DR-11 · 200 PSI · 3/4" · 12 GPM
DR-11 · 200 PSI · 3/4" · I.D. 0.860" · 12 GPM · 8.850 PSI/100ft · 6.63 ft/sec ⚠ high velocity
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.