Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
7.677
·
Velocity:
6.49
ft/sec
⚠ high velocity
DR-7 · 333 PSI · 1" · 14 GPM
DR-7 · 333 PSI · 1" · I.D. 0.939" · 14 GPM · 7.677 PSI/100ft · 6.49 ft/sec ⚠ high velocity
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.