Friction Loss Calculator
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI Loss per 100 ft
5.088
Velocity (ft/sec)
5.57
⚠ Velocities over 5 ft/sec should be selected with caution.
SIDR · All PSI · 1" · 15 GPM
SIDR · All PSI · 1" · I.D. 1.049" · 15 GPM · 5.088 PSI Loss per 100 ft · 5.57 ft/sec ⚠ high velocity
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.