Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
5.163
·
Velocity:
5.85
ft/sec
⚠ high velocity
DR-13.5 · 160 PSI · 1" · 18 GPM
DR-13.5 · 160 PSI · 1" · I.D. 1.121" · 18 GPM · 5.163 PSI/100ft · 5.85 ft/sec ⚠ high velocity
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.