Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
0.957
·
Velocity:
2.96
ft/sec
DR-13.5 · 160 PSI · 1-1/2" · 19 GPM
DR-13.5 · 160 PSI · 1-1/2" · I.D. 1.618" · 19 GPM · 0.957 PSI/100ft · 2.96 ft/sec
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.