Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
0.381
·
Velocity:
2.10
ft/sec
SIDR · All PSI · 2" · 22 GPM
SIDR · All PSI · 2" · I.D. 2.067" · 22 GPM · 0.381 PSI/100ft · 2.10 ft/sec
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.