Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
6.517
·
Velocity:
11.95
ft/sec
⚠ high velocity
DR-11 · 200 PSI · 3" · 240 GPM
DR-11 · 200 PSI · 3" · I.D. 2.864" · 240 GPM · 6.517 PSI/100ft · 11.95 ft/sec ⚠ high velocity
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.