Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
0.677
·
Velocity:
2.87
ft/sec
SIDR · All PSI · 2" · 30 GPM
SIDR · All PSI · 2" · I.D. 2.067" · 30 GPM · 0.677 PSI/100ft · 2.87 ft/sec
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.