Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
7.631
·
Velocity:
5.29
ft/sec
⚠ high velocity
SDR-9 · 250 PSI · 3/4" · 6 GPM
SDR-9 · 250 PSI · 3/4" · I.D. 0.681" · 6 GPM · 7.631 PSI/100ft · 5.29 ft/sec ⚠ high velocity
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.