Friction Loss Calculator
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI Loss per 100 ft
8.247
Velocity (ft/sec)
9.46
⚠ Velocities over 5 ft/sec should be selected with caution.
SIDR · All PSI · 1-1/2" · 60 GPM
SIDR · All PSI · 1-1/2" · I.D. 1.610" · 60 GPM · 8.247 PSI Loss per 100 ft · 9.46 ft/sec ⚠ high velocity
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.