Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
12.504
·
Velocity:
11.22
ft/sec
⚠ high velocity
DR-9 · 250 PSI · 1-1/2" · 60 GPM
DR-9 · 250 PSI · 1-1/2" · I.D. 1.478" · 60 GPM · 12.504 PSI/100ft · 11.22 ft/sec ⚠ high velocity
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.