Friction Loss Calculator
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI Loss per 100 ft
1.087
Velocity (ft/sec)
2.61
DR-7 · 333 PSI · 1-1/4" · 9 GPM
DR-7 · 333 PSI · 1-1/4" · I.D. 1.186" · 9 GPM · 1.087 PSI Loss per 100 ft · 2.61 ft/sec
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.