Flow Loss Nomograph
Williams-Hazen formula · C = 150 (thermoplastic pipe)
GPM
PSI/100ft:
5.180
·
Velocity:
8.61
ft/sec
⚠ high velocity
SIDR · All PSI · 2" · 90 GPM
SIDR · All PSI · 2" · I.D. 2.067" · 90 GPM · 5.180 PSI/100ft · 8.61 ft/sec ⚠ high velocity
Values are calculated using the Williams-Hazen formula (C = 150) and are provided for reference only. Interstate Plastic, Inc. makes no warranty as to accuracy or fitness for any particular use. Consult a licensed engineer for system design.